    Eaton Rack PDU G4

    With its market-leading cybersecurity, global approval and versatility within deployments, the Rack PDU G4 is ideal for data center managers seeking to streamline PDU procurement and management.
    Contact me about this product View Resources
Eaton G4 Rack PDU EVMA1530X front view

The Rack PDU G4 has a small footprint that saves space for revenue-generating equipment

Industry-leading, high-density 0U mounted PDU that provides 24, 42 or 48 evenly distributed outlets on a 42U chassis. Its low-profile circuit breakers are flush with the chassis, and its narrow, single-wide (2 in.) width provides multiple mounting options.

High power, high density up to 46kW

All new HDX PDU G4 delivers enterprise quality power distribution to GPU-intensive rack infrastructures for applications like generative AI that require high-power density.

Implementing Zero-Touch Provisioning with Eaton Gigabit Network Interfaces

High Power/High Density Models (HDX)

Catalog Number Technology Form Factor Plug Type Phase Voltage Current (3) Outlets (4) Power rating Cord length Dimensions (H x W x D)
EMAGLFA5A2A5A2L Managed 0U (vertical) 460P9W 3P 208V Delta 60A 54 (42/0/12) 17 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGLFA5A5A5A5L Managed 0U (vertical) 460P9W 3P 208V Delta 60A 48 (24/0/24) 17 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGLFC2C2C2C2L Managed 0U (vertical) 460P9W 3P 208V Delta 60A 48 (48/0/0) 17 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGLFC3C3C3C3L Managed 0U (vertical) 460P9W 3P 208V Delta 60A 36 (24/0/12) 17 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGLFC4C4C4C4L Managed 0U (vertical) 460P9W 3P 208V Delta 60A 24 (0/0/24) 17 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGMFA5A2A5A2L Managed 0U (vertical) 4100P9W 3P 208V Delta 80A 54 (42/0/12) 29 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGMFA5A5A5A5L Managed 0U (vertical) 4100P9W 3P 208V Delta 80A 48 (24/0/24) 29 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGMFC2C2C2C2L Managed 0U (vertical) 4100P9W 3P 208V Delta 80A 48 (48/0/0) 29 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGMFC3C3C3C3L Managed 0U (vertical) 4100P9W 3P 208V Delta 80A 36 (24/0/12) 29 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGMFC4C4C4C4L Managed 0U (vertical) 4100P9W 3P 208V Delta 80A 24 (0/0/24) 29 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGFFA4A4A4A4L Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 48 (24/24/0) 35 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGFFA5A2A5A2L Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 54 (42/0/12) 35 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGFFA5A5A5A5L Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 48 (24/0/24) 35 kW 6 ft. 76 x 4.1 x 2.5 in.
EMAGFFC2C2C2C2L Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 48 (48/0/0) 35 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGFFC3C3C3C3L (1) Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 36 (24/0/12) 35 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGFFC4C4C4C4L (1) Managed 0U (vertical) 560P6W 3P 240/415V Wye (2) 60A 24 (0/0/24) 35 kW 6 ft. 69.4 x 4.1 x 2.5 in.
EMAGKEA4A4A4A4L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 48 (24/24/0) 36 kW None 76 x 4.1 x 2.5 in.
EMAGKEA5A2A5A2L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 54 (42/0/12) 36 kW None 76 x 4.1 x 2.5 in.
EMAGKEA5A5A5A5L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 48 (24/0/24) 36 kW None 76 x 4.1 x 2.5 in.
EMAGKEC2C2C2C2L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 48 (48/0/0) 36 kW None 69.4 x 4.1 x 2.5 in.
EMAGKEC3C3C3C3L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 36 (24/0/12) 36 kW None 69.4 x 4.1 x 2.5 in.
EMAGKEC4C4C4C4L Managed 0U (vertical) Hardwired 3P 208V Delta 100A 24 (0/0/24) 36 kW None 69.4 x 4.1 x 2.5 in.
EMAGECA5A2A5A2L Managed 0U (vertical) Hardwired 3P 240/415V Wye (2) 64A 54 (42/12/0) 46 kW None 76 x 4.1 x 2.5 in.
EMAGECA5A5A5A5L Managed 0U (vertical) Hardwired 3P 240/415V Wye (2) 64A 48 (24/0/24) 46 kW None 76 x 4.1 x 2.5 in.
EMAGECC2C2C2C2L Managed 0U (vertical) Hardwired 3P 240/415V Wye (2) 64A 48 (48/0/0) 46 kW None 69.4 x 4.1 x 2.5 in.
EMAGECC3C3C3C3L Managed 0U (vertical) Hardwired 3P 240/415V Wye (2) 64A 36 (24/0/12) 46 kW None 69.4 x 4.1 x 2.5 in.
EMAGECC4C4C4C4L Managed 0U (vertical) Hardwired 3P 240/415V Wye (2) 64A 24 (0/0/24) 46 kW None 69.4 x 4.1 x 2.5 in.
Due to continuous improvement programs, all specifications are subject to change without notice. (1) Stocked PDU with shorter lead time. Other PDUs listed are built to order. (2) Supports 220/380V Wye, 230/400V Wye and 240/415V Wye. (3) Derated current for corded PDUs is 80% of maximum current. (4) The C39 outlet combines the functionality of C13 and C19 outlets to accommodate both C14 and C20 plugs. 
spacer

Standard Models (Corded)

Catalog Number Technology Form Factor Plug Type Phase Voltage Current Outlets Power Rating Cord Length
EVMIL630X Metered 0U (vertical) L6-30 1P 208V 30A 42 outlets (24)C13 (18)C39 5.8kW 10ft
EVMAL630X Managed 0U (vertical) L6-30 1P 208V 30A 42 outlets (24)C13 (18)C39 5.8kW 10ft
EVMI2120X Metered 0U (vertical) L21-20 3P 120/208V 20A 42 outlets (24)C13 (18)C39 5.8kW 10ft
EVMI1530X Metered 0U (vertical) L15-30 3P 208V 30A 42 outlets (24)C13 (18)C39 8.6kW 10ft
EVMA1530X Managed 0U (vertical) L15-30 3P 208V 30A 42 outlets (24)C13 (18)C39 8.6kW 10ft
EVMI2130X Metered 0U (vertical) L21-30 3P 120/208V 30A 42 outlets (24)C13 (18)C39 8.6kW 10ft
EVMA2130X Managed 0U (vertical) L21-30 3P 120/208V 30A 42 outlets (24)C13 (18)C39 8.6kW 10ft
EVMI8365X Metered 0U (vertical) CS8365 3P 208V 50A 42 outlets (24)C13 (18)C39 14.4kW 10ft
EVMA8365X Managed 0U (vertical) CS8365 3P 208V 50A 42 outlets (24)C13 (18)C39 14.4kW 10ft
EVMI4609X-06 Metered 0U (vertical) 460P9W 3P 208V 60A 42 outlets (24)C13 (18)C39 17.3kW 6ft
EVMI4609X Metered 0U (vertical) 460P9W 3P 208V 60A 42 outlets (24)C13 (18)C39 17.3kW 10ft
EVMA4609X-06 Managed 0U (vertical) 460P9W 3P 208V 60A 42 outlets (24)C13 (18)C39 17.3kW 6ft
EVMA4609X Managed 0U (vertical) 460P9W 3P 208V 60A 42 outlets (24)C13 (18)C39 17.3kW 10ft
EVMIL620A Metered 0U (vertical) C20Plug/L6-20 1P/2P 100-240V 16A 24 outlets (12)C13 (12)C39 3.8kW 10ft
EVMAL620A Managed 0U (vertical) C20Plug/L6-20 1P/2P 100-240V 16A 24 outlets (12)C13 (12)C39 3.8kW 10ft
EVMAL630A Managed 0U (vertical) L6-30 1P 208V 30A 24 outlets (12)C13 (12)C39 5.8kW 10ft
EVMA2120A Managed 0U (vertical) L21-20 3P 120/208V 20A 24 outlets (12)C13 (12)C39 5.8kW 10ft
EVMAL630B Managed 0U (vertical) L6-30 1P 208V 30A 20 outlets (10)C13 (10)C39 5.8kW 10ft
EVMA2130A Managed 0U (vertical) L21-30 3P 120/208V 30A 24 outlets (12)C13 (12)C39 8.6kW 10ft
EVMA1530A Managed 0U (vertical) L15-30 3P 208V 30A 24 outlets (12)C13 (12)C39 8.6kW 10ft
EVMIG332X Metered 0U (vertical) 532P6W 3P 240/415V 32A 42 outlets (24)C13 (18)C39 17.3kW 10ft
EVMAG332X Managed 0U (vertical) 532P6W 3P 240/415V 32A 42 outlets (24)C13 (18)C39 17.3kW 10ft
EVMAG332C Managed 0U (vertical) 532P6W 3P 240/415V 32A 48 outlets (24)C13 (24)C39 17.3kW 10ft
spacer

Universal Input Models (UPDU)

Catalog number Technology Form factor Input plug Voltage Current Input connection (on chassis) Outlets Power Rating Dimensions (H x W x D)
EVMAGU23X Managed 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, front entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
EVMAGU23X-E Managed 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
EVBAGU23X-E Basic 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
64 x 2.1 x 2.6 in.
(162.5 x 5.3 x 6.5 cm)
EVMIGU23A-E Metered Input 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 24: (x12) C13; (x12) C39 Up to 23 kW,
varies by input cable
55.9 x 2.1 x 2.6 in.
(142 x 5.3 x 6.5 cm)
EVMIGU23X Metered Input 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, front entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
EVMIGU23X-E Metered Input

0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
EVMAGU23A-E Managed 0U (vertical) 15 options, see below Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 24: (x12) C13; (x12) C39 Up to 23 kW,
varies by input cable
55.9 x 2.1 x 2.6 in.
(142 x 5.3 x 6.5 cm)
EVMOGU23X-E Metered Outlet 0U (vertical)
15 options, see below
Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 42: (x24) C13; (x18) C39 Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
 EVMOGU23X Metered Outlet 0U (vertical)
15 options, see below
Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 42: (x24) C13; (x18) C39

Up to 23 kW,
varies by input cable
72 x 2.1 x 2.6 in.
(183 x 5.3 x 6.5 cm)
EVMOGU23A-E Metered Outlet 0U (vertical)
15 options, see below
Input cable determines single- or three-phase wiring & voltage 16-55A 8-pin, end entry 24: (x12) C13; (x12) C39

Up to 23 kW,
varies by input cable
55.9 x 2.1 x 2.6 in.
(142 x 5.3 x 6.5 cm)

*INPUT CABLE SPECIFICATIONS

Part number Plug Length Region Panel breaker De-rated current Voltage Power phase Max power per PDU
CBL350-10 L6-30 10 ft. (3 m) AMER 30A 24A 208V Single 5.0 kVA
CBL354-10 332P6W 10 ft. (3 m) AMER 30A 24A 240V Single 5.8 kVA
EMEA/APAC 32A 32A 230V Single 7.4 kVA
CBL367-10 L21-20 10 ft. (3 m) AMER 20A 16A 208V WYE Three 5.8 kVA
CBL365-10 L15-30P 10 ft. (3 m) AMER 30A 24A 208V Delta Three 8.6 kVA
CBL351-10 L21-30 10 ft. (3 m) AMER 30A 24A 208/120V WYE Three 8.6 kVA
CBL362-10 360P6W 10 ft. (3 m) AMER 60A 48A 240V Single 11.5 kVA
CBL355-10 516P6W 10 ft. (3 m) AMER 20A 16A 240/415V WYE Three 11.5 kVA
EMEA/APAC 16A 16A 230/400V WYE Three 11.0 kVA
CBL364-06 CS8365 6 ft. (1.8 m) AMER 50A 40A 208V Delta Three 14.4 kVA
CBL364-10 CS8365 10 ft. (3 m) AMER 50A 40A 208V Delta Three 14.4 kVA
CBL356-06 460P9W 6 ft. (1.8 m) AMER 60A 48A 208V Delta Three 17.3 kVA
CBL356-10 460P9W 10 ft. (3 m) AMER 60A 48A 208V Delta Three 17.3 kVA
CBL366-10 560P9W 10 ft. (3 m) AMER 60A 48A 208/120V WYE Three 17.3 kVA
CBL357-10 Hardwired 3P + PE, 6 AWG 10 ft. (3 m) AMER 60A 48A 208V Delta Three 17.3 kVA
CBL368-10 L22-30 10 ft. (3 m) AMER 30A 24A 240/415V WYE Three 17.3 kVA
CBL358-10 532P6W 10 ft. (3 m) AMER 30A 24A 240/415V WYE Three 17.3 kVA
EMEA/APAC 32A 32A 230/400V WYE Three 22.1 kVA
CBL360-10 560P6W 10 ft. (3 m) AMER 40A or 60A 32A 240/415V WYE Three 23.0 kVA
CBL369-10 Hardwired 3P + N + PE, 8 AWG 10 ft. (3 m) AMER 40A 32A 240/415V WYE Three 23.0 kVA
spacer

Global approval

The Rack PDU G4 meets industry standards used all over the world, with power ratings ranging from 3 kW up to 23 kW and seven universal input (UPDU) models that can be paired with any one of 17 detachable input cables with plug types to match the electrical standards in different regions.

Outlets that give you options

High-retention, P-lock compatible C39 outlets accept both C14 and C20 plugs, adding flexibility to deployments and reducing the quantity of PDUs you will need to purchase and install. Fewer PDUs also means more rack space for revenue-generating equipment.

Hot swappable network module

The hot-swappable Gigabit Network Module (GNM) module can be removed or upgraded without interrupting power to the PDU. With dual GbE ports, you can easily cascade up to 40 PDUs and share the same network connection with individual IP addresses, simplifying management, freeing up space and cutting costs. (excludes basic models)

Market-leading cybersecurity

The Rack PDU G4 includes a user-configurable firewall. Managed, metered input and metered outlet models offer market-leading cybersecurity capabilities, including zero-trust architecture and zero-touch provisioning via the integrated gigabit network module and the only PDU on the market with UL 2900-1 and IEC 62443-4-2 cybersecurity certifications.

Eaton Universal Input Rack PDU (UPDU)

A single solution equipped to meet the most diverse data center rack power needs. With its universal input, dynamic C39 outlets and global approval, the UPDU accommodates single- and 3-phase power in 208V and 415/240V environments, as well as equipment with a variety of connectors and power demands. By deploying the UPDU, you can save time, reduce costs, and simplify power management for single data centers or global projects across multiple locations.

Painless box-to-rack experience

Toolless mounting buttons offer multiple mounting options to fit your rack’s layout and power needs. It can be mounted front- or side-facing by simply moving the mounting buttons into prefabricated hole punches that ensure each button is placed correctly for your preferred configuration.

Maximize your investment with software

For larger deployments spanning multiple locations, the Rack PDU G4's integrate smoothly via SNMP with digital solutions from our Brightlayer Data Centers suite. This includes Distributed IT Performance Management (DITPM) and Data Center Performance Management (DCPM) software, and our cloud-based Remote Monitoring Service, also known as PredictPulse™, which is an around-the-clock service that aggregates data from your rack PDUs and dispatches an Eaton field technician when a critical event occurs.

Find the right rack PDU for your IT needs

Specify basic, metered input, metered outlet or managed PDUs, also known as switched PDUs, in addition to several other key features.

Have more questions about power distribution?

 

Product resources