700W PowerVerter APS 12VDC 120V Inverter/Charger with Auto-Transfer Switching, 1 Outlet
Delivering Reliable Power Away from Standard AC Outlets
This inverter/charger is a reliable power source for a wide variety of equipment ranging from power tools and pumps to portable lighting and computer equipment in heavy-load conditions. With no fumes, fuel or excess noise, it’s an excellent alternative to generator power. It converts stored power from a DC battery source to safe, stable, computer-grade AC power for unlimited runtime.
Recommended for Mobile, Emergency and Remote Sites
Designed for easy installation in RVs, commercial and fleet vehicles, emergency vehicles and construction equipment, this power inverter is ideal for powering tools, saws, motors, pumps, portable lighting, appliances and computer equipment in heavy-load conditions.
Meets Normal and Peak Power Demands
The DC-to-AC inverter features an automatic line-to-battery transfer switch and integrated charging system that allow it to work as a vehicle inverter, standalone AC power source or extended-run UPS system. An automatic overload detector, cooling fan and resettable AC circuit breakers protect the unit from damage.
Serves as a Battery Charger
When external AC power is supplied and powering connected equipment, this charger/inverter keeps the user-supplied battery charged while simultaneously delivering AC power to connected equipment.
| Product Name |
Eaton Tripp Lite series PowerVerter power inverter and charger
|
| Catalog Number |
APS700HF
|
| UPC |
037332126948
|
| Product Length/Depth |
8.5 in
|
| Product Height |
8.5 in
|
| Product Width |
14.5 in
|
| Product Weight |
4 lb
|
| Compliances |
RoHS
|
| Product Type |
Power inverter and charger
|
| Special features |
Important Note_x000D_
_x000D_
Position a 125A fuse link less than 18 in. from the battery in the positive line to protect against high-current draw that may occur during inverter failure.
|
| Battery Charge |
6A max, steps down to float level to maintain
|
| Expandable Battery Runtime |
Runtime is expandable with any number of user supplied wet, gel or SLA type batteries
|
| Expandable Runtime Description |
Runtime is expandable with any number of user supplied wet, gel or SLA type batteries
|
| High Voltage Transfer to Battery Power |
In AC "auto" mode, inverter/charger switches to battery mode as line voltage increases to 139V
|
| Transfer Time (Line Power to Battery Mode) |
16.6 milliseconds (typical - compatible with many computers, servers and networking equipment - verify transfer time compatibility of loads for UPS applications)
|
| Low Voltage Transfer to Battery Power |
In AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 85V (user adjustable to 85, 95V - see manual)
|
| AC Suppression Joule Rating |
300
|
| Continuous Output Capacity (Watts) |
700
|
| Cooling Method |
Multi-speed fan
|
| DC System Voltage (VDC) |
|
| Form Factor Supported |
Integrated mounting feet for easy installation
|
| Front Panel LEDs |
6 diagnostic LEDs indicate battery voltage level (high, medium & low) and operation (line, inverter, load)
|
| Input Connection Type |
DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: NEMA 5-15P input plug
|
| LED Indicators |
6 diagnostic LEDs indicate battery voltage level (high, medium & low) and operation (line, inverter, load)
|
| Amperage Rating per watt |
DC INPUT: Full continuous load - 72A at 12V DC. AC INPUT: 8.4 amps at 120VAC with full inverter and charger load (1.4A max charger-only)
|
| Output Frequency Regulation |
60 Hz (+/- 0.3 Hz)
|
| Output Voltage Regulation |
LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains PWM sine wave output voltage of 120 V AC (+/-5%).
|
| Overload Protection |
Includes 7A output breaker for AC output loads
|
| Peak Output Capacity (Watts) |
1400
|
| Power Cord Jacket Type |
SJT
|
| Frequency Compatability |
60 Hz
|
| Recommended Electrical Service |
DC INPUT: Requires 12V DC input source capable of delivering 72A for the required duration (when used at full continuous capacity - DC requirements increase during Over-Power and Double-Boost operation). AC INPUT: 15A 120V AC recommended
|
| Relative Humidity |
0-95% non-condensing
|
| Switches |
3 position DC off, auto (inverter or AC) and charge-only switch enables simple operation
|
| Voltage Compatibility (VDC) |
12
|
| Material |
Aluminum
|
| Output Receptacles |
5-15R
|
| Package Contents |
Owner’s manual
APS700HF 700W PowerVerter APS 12V DC 120V AC Inverter/Charger |
| Input Nominal Voltage |
120 VAC
|
| Product Features |
Expandable Runtime
DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: NEMA 5-15P input plug |
| Product Highlights |
Delivers clean 120V AC power from AC or DC power source
Protects against blackouts, surges and EMI/RFI line noise Compact, lightweight aluminum housing weighs just 4 lb. 700W continuous output power; 1400W peak power Auto-transfer switching option for UPS operation |
| Nominal Output Voltage |
120V
|
| Form Factor |
Integrated mounting feet for easy installation
|
| Voltage Compatibility (VAC) |
120 VAC
|