OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial
| Product Name |
Eaton Tripp Lite series OmniSmart UPS
|
| Catalog Number |
OMNISMART350HG
|
| UPC |
037332098542
|
| Product Length/Depth |
10.1 in
|
| Product Height |
14 in
|
| Product Width |
8 in
|
| Product Weight |
25 lb
|
| Compliances |
RoHS
FCC Class B |
| Certifications |
UL Listed
UL 1778 CSA certified |
| Global Catalog |
OMNISMART350HG
|
| Product Type |
UPS
|
| Topology |
Line-interactive
|
| Package contents |
|
| Input connection |
5-15P-HG
|
| Input frequency range |
60 Hz
|
| Electric current - max |
2.3A
|
| Battery replacement |
RBC52 (quantity 2)
|
| Runtime at half load |
46 min
|
| Relative humidity |
0-95% non-condensing
|
| Output Receptacles |
5-15R
|
| Output Receptacles Details |
Hospital grade output receptacles
|
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
120V
|
| Network Management Cards Details |
Network management not supported
|
| Communication interface |
DB9 Serial
|
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
DB9 serial cable included
|
| Grounding Details |
Grounding lug
|
| Input Circuit Breakers |
3.5A
|
| Output Isolation Transformer |
Hospital grade load isolation transformer
|
| High Voltage Transfer to Battery Power |
139
|
| Low Voltage Transfer to Battery Power |
89
|
| Undervoltage Correction |
Input voltages between 89 and 107 are boosted by 14%
|
| Application |
Hospital/Medical
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation
|
| Housing material |
PVC
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.33
|
| Output Capacity (kW) |
0.225
|
| Output Capacity (VA) |
330
|
| Primary UPS Depth (mm) |
183
|
| Primary UPS Height (mm) |
274
|
| Primary UPS Width (mm) |
132
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
4 LEDs indicate line power, battery power, overload and battery low/replace status
|
| Output Voltage Regulation (Line Mode) |
-18%, +8%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90%
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
|
| Maximum Input Amps |
2
|
| UPS Input Cord Length (m) |
1.8
|
| UPS Power Module Dimensions |
10.8 x 5.2 x 7.2
|
| Power Mode Transfer Time |
2-4 milliseconds
|
| Optional Accessories |
Wallmount (UPSWM - tower mounting kit)
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P-HG
|
| UPS Dataline Suppression |
2 line TEL/DSL
|
| High Availability UPS Features |
Hot swappable batteries
Surge/noise protection |
| Primary Form Factor |
Tower
|
Support from Eaton